COOLING AND LUBRICATION SYSTEM 6-11
INSTALLATION
Install a new sealing washer
1.
Tighten the ECT sensor to the specified torque.
$ ECT sensor: 19 N·m (1.9 kgf-m, 13.5 lb-ft)
!
Pour engine coolant. (#2-18)
Bleed air from the cooling circuit. (#2-19)
Take special care when handling the ECT sensor. It
may cause damage if it gets a sharp impact.