8-8 ELECTRICAL SYSTEM
Step4
1) Measure the continuity of the generator coil. (!8-10)
Is the resistance of generator coil OK?
Step5
1) Measure the generator no-load voltage. (!8-10)
Is generator no-load performance OK?
Step6
1) Inspect the regulator/rectifier. (!8-11)
Is the regulator/rectifier OK?
Step7
1) Inspect the wire harness.
Is the wire harness OK?
Battery overcharges
Faulty regulator/rectifier.
Faulty battery.
Poor contact of generator lead wire coupler.
YES Go to Step5.
NO
Faulty generator coil.
Disconnected lead wires.
YES Go to Step6.
NO Faulty generator.
YES Go to Step7.
NO Faulty regulator/rectifier.
YES Faulty battery
NO
Short circuit of wire harness.
Poor contact of coupler.