8-8 ELECTRICAL SYSTEM
Y
Y
Y
Y
Y
Y
GENERATOR COIL RESISTANCE
Remove the secondary gear case cover.
Disconnect the generator coupler.
Measure the resistance between the three lead wires.
If the resistance is not specified value, replace the stator with a
new one. Also, check that the generator core is insulated.
# 09900-25008: Multi circuit tester set
' Tester knob indication: Resistance ()
$ Generator coil resistance:0.2 1.5 (Yellow – Yellow)
(Yellow – Ground)
NOTE:
When making above test, it is not necessary to remove the gen-
erator.
GENERATOR NO-LOAD PERFORMANCE
Start the engine and keep it running at 5 000 r/min.
Using the multi circuit tester, measure the voltage between three
lead wires.
If the tester reads under the specified value, replace the gen-
erator with a new one.
# 09900-25008: Multi circuit tester set
( Tester knob indication: Voltage (
)
$ Generator no-load performance (When engine is
cold): More than 70 V at 5 000 r/min
REGULATED VOLTAGE
Remove the two seats. (!7-2)
Start the engine and keep it running at 5 000 r/min. with light-
ing switch turned ON (except for E-03, 28, 24, 33 models) and
dimmer switch turned HI position.
Measure the DC voltage between the + and - battery termi-
nals using the multi circuit tester. If the voltage is not within the
specified value, inspect the generator and regulator/rectifier.
(!8-8 and 8-9)
NOTE:
When making this test, be sure that the battery is in fully-charged
condition.
# 09900-25008: Multi circuit tester set
( Tester knob indication: Voltage (
&&
&
&)
$ Charging output (Regulated voltage):
14.0 – 15.5 V at 5 000 r/min.
DCV
+
-
Ba ery