8-26 ELECTRICAL SYSTEM
(Top)
(Bottom)
FUEL LEVEL GAUGE INSPECTION
• Remove the fuel tank. (&5-3)
• Remove the fuel level gauge.
Measure the resistance at each fuel level gauge float position. If
the resistance is incorrect, replace the fuel level gauge with a
new one.
Float position Resistance
A “F” (Full) 4 – 10 Ω
B “E” (Empty) 90 – 100 Ω
Remount the fuel level gauge in the reverse order of removal. Pay
attention to the following points.
• Install the O-ring and apply grease to it.
For U.S.A.
+ 99000-25030: SUZUKI SUPER GREASE “A”
For the other countries
+ 99000-25010: SUZUKI SUPER GREASE A”
!
Use a new O-ring to prevent fuel leakage.
• Face the “ ” mark 1 on the fuel level gauge forward.
• Lightly tighten the bolts in a crisscross pattern, and then tighten
them to the specified torque in the above manner.
, Fuel level gauge bolt: 10 N
.
m (1.0 kgf
.
m, 7.0 lb-ft)