3-18 ENGINE
NEUTRAL SWITCH
Remove the neutral switch assembly.
Remove the oil pressure switch lead wire.
GENERATOR
Remove the generator cover.
Remove the starter motor driven gear and the idle gear.
Loosen the generator rotor bolt.
NOTE:
When loosen the rotor bolt, do not remove it. The rotor bolt is
used in conjunction with the rotor remover when removing the
rotor.
Remove the generator rotor assembly with the special tool.
Remove the key.
% 09930-33730: Rotor remover