6
Close the lever.
7
Make sure that the drive status LED turns green.
See “Removing and replacing appliance hardware components” on page 100.
Removing and replacing a NetBackup 5220 Appliance
power supply
The NetBackup 5220 Appliance has two power supplies to provide fault-tolerant
operation. If one power supply fails, the other provides power to the appliance until
the faulty power supply is replaced.
Power supplies are hot swappable. You can replace one while the appliance is in
operation. At least one power supply must be functioning for the appliance to
operate.
Caution: Do not leave a power supply bay empty for longer than 3 minutes. The
NetBackup 5220 appliance is constructed for optimum air circulation when the unit
is in operation. The appliance can overheat and damage vital components if a power
supply bay is empty for longer than three minutes while the appliance is in operation.
Requirements
■ Replacement NetBackup 5220 power supply from Symantec.
To remove and replace a NetBackup 5220 power supply:
1
Locate the replacement power supply module and remove the protective
packaging. Set the power supply near the appliance requiring repair so that it
can be installed quickly.
2
Disconnect the power cable from the faulty power supply.
3
Press in and hold the green lever on the right side of the power supply to
release the module.
4
Grasp the handle between the two fans in the power supply module and pull
the module out of the slot.
5
Orient the replacement power supply so that the green lever is on the right
side of the appliance.
6
Insert a new power supply module until it clicks into place.
7
Plug the power cable into the power socket in the module.
See “Removing and replacing appliance hardware components” on page 100.
108Removing and replacing appliance hardware components
Removing and replacing a NetBackup 5220 Appliance power supply