Issue 2: Sep 99 TMSL 097-44018-26
Page 117
COMMAND CODE: RTRV-PM-PORT (Contd)
EXAMPLE
For MTIE (TDEV will appear similarly):
Input:
RTRV-PM-PORT::PSM-1-4:141::MTIE,,,,,,12-00;
Response:
TOP523 1997-09-06 13:47:09
M 141 COMPLD
"PSM-1-4:MTIE1,3,,2,,2,,2,,,,,1997-09-06,12:00:00"
"PSM-1-4:MTIE4,6,,4,,4,,5,,,,,1997-09-06,12:00:00"
"PSM-1-4:MTIE16,7,,5,,5,,7,,,,,1997-09-06,12:00:00"
"PSM-1-4:MTIE64,7,,8,,9,,8,,,,,1997-09-06,12:00:00"
"PSM-1-4:MTIE128,10,,8,,9,,9,,,,,1997-09-06,12:00:00"
"PSM-1-4:MTIE512,13,,9,,10,,12,,,,,1997-09-06,12:00:00"
"PSM-1-4:MTIE900,16,,10,,10,,12,,,,,1997-09-06,12:00:00"
;
The above example, tagged as command 141, retrieves the MTIE performance monitoring data for
port 4 of PSM-1 for 1 hour after 12:00 PM on Sept. 6, 1997.