Issue 2: Sep 99 TMSL 097-44018-26
Page 17
COMMAND CODE: ACT-USER
PURPOSE
ACTIVATE USER
This command logs the user onto the system and begins a session. The user name and password are case sen-
sitive (uppercase/lowercase) and must be entered exactly as assigned. After a period of inactivity (set in the
ED-COM command), the user is automatically logged off.
INPUT FORMAT
ACT-USER:[<tid>]:<uid>:<ctag>::<pid>;
EXAMPLE
Input:
ACT-USER:SANJOSE-114:BIG:155::SQUIRT;
Response:
SANJOSE-114 1997-12-08 15:04:13
M 155 COMPLD
;
This example, tagged as command 155, logs onto the designated
<tid>
with the username BIG and the
password
SQUIRT
to begin a session.
parameter value meaning
uid user name the user logging on
pid password the user’s password