COMMAND CODE: ENT-USER-SECU
PURPOSE
ENTER USER SECURITY
This command enters a new user including the user’s name, password, and access level. The user name
and password are case (uppercase/lowercase) sensitive, therefore use care when assigning these param-
eters. One user is assigned at the factory, and up to 16 additional users can be assigned (for a total of 17
users).
INPUT FORMAT
ENT-USER-SECU:[<tid>]:<uid>:<ctag>::<pid>,,<uap>;
EXAMPLE
Input:
ENT-USER-SECU::BIG:155::CLOUD,,3;
Response:
SANJOSE-114 1997-12-08 15:04:13
M 155 COMPLD
;
This example, tagged as command 155, changes the access level to 3 for user BIG whose password is
CLOUD.
parameter values meaning
uid up to 10 alpha-numeric characters user name
pid up to 10 characters (see note be-
low)
password identification
uap 1–5 user access level (5 is highest level)
Note: The password can have a minimum of 1 character and a maximum of 10 characters. At least one alpha
character must be used. Alpha characters can be uppercase, lowercase, or a mixture of both. Any printable char-
acter can be used except: comma (,), colon (:), semicolon (;), null (), space ( ), ampersand (&), and equal sign (=).

Table of Contents

Other manuals for Symmetricom TimeProvider 500 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 500 series and is the answer not in the manual?

Symmetricom TimeProvider 500 series Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 500 series
CategoryData Loggers
LanguageEnglish

Related product manuals