Issue 2: Sep 99 TMSL 097-44018-26
Page 25
COMMAND CODE: DLT-EQPT
PURPOSE
DELETE EQUIPMENT
This command deletes equipment from the system database.
INPUT FORMAT
DLT-EQPT:[<tid>]:<aid>:<ctag>;
The parameter values in the table below are as follows:
a = 1–2 b = 1–11 c = 1–12 (1–10 for TOTA-5 & TOTA-M)
EXAMPLE
Input:
DLT-EQPT::PSM-5:134;
Response:
SANJOSE-114 1997-12-08 15:04:13
M 134 COMPLD
;
This example, tagged as command 134, deletes PSM-5 from the system database.