TMSL 097-44018-26 Issue 2: Sep 99
Page 122
COMMAND CODE: RTRV-SSM-EQPT
PURPOSE
RETRIEVE SYNCHRONIZATION STATUS MESSAGING EQPT
This command displays the quality level assigned by the ED-SSM-EQPT command to the output sig-
nal(s) of an input card or the output signals of TOTA-M, EA10-M, EA20-M, GTI-17, or GTI-18 cards. Also
displayed are the SSM trouble code to be sent out during clock holdover, and whether to use the Sa4
through Sa8 bits of an E1 signal for SSM messages.
INPUT FORMAT
RTRV-SSM-EQPT:[<tid>]:<aid>:<ctag>;
The parameter values in the table below are as follows:
a = 1–2 or ALL b = 1–12 or ALL
RESPONSE FORMAT
<sid> <date> <time>
M <ctag> COMPLD
"<aid>:<ssmmsg>[,[<ssmtc>][,<ssmsa4>,<ssmsa5>,<ssmsa6>,
<ssmsa7>,<ssmsa8>]]"
;
Notes:
1. The <ssmtc> parameter appears only for EA10-M, EA20-M, and TOTA-M cards.
2. The parameters <ssmsa4>, <ssmsa5>, <ssmsa6>, <ssmsa7>, and <ssmsa8> appear only for
DCIM-EA and GTI-18 cards.
aid for card meaning
DCIM-a DCIM-T, DCIM-EA Specified DCIM card
GTI-a GTI-17, GTI-18 Specified GTI card
INPUT-a Input Specified input card other than DCIM card
TO-b TOTA-M, EA10-M,
EA20-M
Specified output card

Table of Contents

Other manuals for Symmetricom TimeProvider 500 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 500 series and is the answer not in the manual?

Symmetricom TimeProvider 500 series Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 500 series
CategoryData Loggers
LanguageEnglish

Related product manuals