EasyManuals Logo

Symmetricom TimeProvider 500 series Reference Guide

Symmetricom TimeProvider 500 series
165 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #33 background imageLoading...
Page #33 background image
Issue 2: Sep 99 TMSL 097-44018-26
Page 33
COMMAND CODE: ED-EQPT
PURPOSE
EDIT EQUIPMENT
This command changes equipment parameters.
Note: This command will be denied when attempting to set the <clklevel> with an aid of CLK unless
one of the following has been completed:
the ENT-EQPT command has been used to enter the DCIM card(s)
the SET-ATTR-CONT command has been used to set the <conttype> for the MIS card to other
than OFF
INPUT FORMAT
ED-EQPT:[<tid>]:<aid>:<ctag>::[<framing>],[<troublecode>],
[<portseverity>],[<osc1>],[<osc2>],[<integration>]
[,[<clklevel>],[<alarmlead>],[<signaltype>]];
Any parameter left blank causes no change to that parameter. The parameter values in the table below
are as follows:
a = 1–2 b = 1–11 c = 12 (1–10 for TOTA-5 & TOTA-M)
aid parameter value meaning
CLK-a framing (null) (not applicable)
troublecode
portseverity
osc1
osc2
integration
clklevel ST2 the clock is an ST2
ST2E the clock is an ST2E
ST3 the clock is an ST3
ST3E the clock is an ST3E
TNC the clock is a TNC
TNCE the clock is a TNCE
alarmlead (null) (not applicable)
signaltype

Table of Contents

Other manuals for Symmetricom TimeProvider 500 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 500 series and is the answer not in the manual?

Symmetricom TimeProvider 500 series Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 500 series
CategoryData Loggers
LanguageEnglish

Related product manuals