COMMAND CODE: RTRV-EQPT
PURPOSE
RETRIEVE EQUIPMENT
This command retrieves framing, trouble code, port severity, oscillator 1 (OSCA) and 2 (OSCB) type, and
the alarm integration time information (where applicable).
INPUT FORMAT
RTRV-EQPT:[<tid>]:<aid>:<ctag>;
The parameter values in the table below are as follows:
a = 1–2 or ALL b = 1–11 or ALL c = 1–12 (1–10 for TOTA-5 & TOTA-M) or ALL
RESPONSE FORMAT
<sid> <date> <time>
M <ctag> COMPLD
"<aid>:[<framing>],[<troublecode>],[<portseverity>],[<osc1>]
,[<osc2>],[<integration>],[<clklevel>],[<alarmlead>],
[<signaltype>]" ...
;
aid meaning
CLK-a CLK card
DCIM-a DCIM card
GTI-a GTI card
LTI -a LT I c a rd
MCA MCA card
MRC-a MRC card
PSM-b PSM card
SHELF all aids for this command
TO-c timing output card