Page #82 background image
TMSL 097-44018-26 Issue 2: Sep 99
Page 82
COMMAND CODE: RTRV-ATTR-CONT
PURPOSE
RETRIEVE ATTRIBUTE CONTROL
This command displays the control preferences set by the SET-ATTR-CONT command.
INPUT FORMAT
RTRV-ATTR-CONT:[<tid>]:<aid>:<ctag>;
OUTPUT FORMAT
<sid> <date> <time>
M <ctag> COMPLD
"<aid>:<conttype>[,<protmode>,
<P1>,<P2>,<P3>,<P4>,<P5>,<P6>,<P7>,<P8>,<P9>,<P10>]"
;
EXAMPLE
Input:
RTRV-ATTR-CONT::SHELF:145;
Response:
SANJOSE-114 1997-12-08 15:04:13
M 145 COMPLD
"SHELF:RVRT"
;
aid meaning
DCIM-ALL DCIM card protection mode (stand-alone or combined)
GTI-ALL SSM mode for GTI-17 and GTI-18 cards (none; SSMT for GTI-17 cards; SSME or SSMEC for
GTI-18 cards)
MCA output protection type for timing output cards other than TO-EA, TO-EA5, EA10, EA10M, EA20,
and EA20M (revertive/nonrevertive, automatic/manual, and protection priority for each output slot)
MIS SSM mode for specified shelf (none; SSMT for DCIM-T and TOTA-M cards; SSME or SSMEC for
DCIM-E, EA-10M, and EA20-M cards)
SHELF output source selection mode (revertive or nonrevertive) for master and all expansion shelves
TO-ALL output protection type for TO-EA, TO-EA5, EA10, EA10M, EA20, and EA20M timing output cards
(none/1 for 1/1 plus 1)

Table of Contents

Other manuals for Symmetricom TimeProvider 500 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 500 series and is the answer not in the manual?

Symmetricom TimeProvider 500 series Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 500 series
CategoryData Loggers
LanguageEnglish

Related product manuals