Issue 2: Sep 99 TMSL 097-44018-26
Page 121
COMMAND CODE: RTRV-REPTMODE-PORT
PURPOSE
RETRIEVE REPORT MODE PORT
This command displays the message type (REPT-ALM-PORT or REPT-ALM-EQPT) used to report au-
tonomous port-alarm messages.
INPUT FORMAT
RTRV-REPTMODE-PORT:[<tid>]::<ctag>;
OUTPUT FORMAT
<sid> <date> <time>
M <ctag> COMPLD
"REPTMODE: <modetype>"
;
Note: Automatic equipment-alarm messages are always reported as REPT-ALM-EQPT messages.
EXAMPLE
Input:
RTRV-REPTMODE-PORT:::119;
Response:
SANJOSE-114 1997-12-08 15:04:13
M 119 COMPLD
"REPTMODE: ALW"
;
This example, tagged as command 119, shows that automatic port-alarm messages will be reported as
REPT-ALM-PORT messages.
modetype meaning
ALW automatic port-alarm messages are reported as a REPT-ALM-PORT
messages
INH automatic port-alarm messages are reported as a REPT-ALM-EQPT
messages