Issue 2: Sep 99 TMSL 097-44018-26
Page 41
COMMAND CODE: ED-PORT
PURPOSE
EDIT PORT
This command modifies the priority, reference type, and signal type mode for a port.
INPUT FORMAT
ED-PORT:[<tid>]:<aid>:<ctag>::[<framing>],[<priority>],
[<reference type>],[<signal type>][,[<reference
condition>]];
Any parameter left blank causes no change to that parameter. The parameter values in the table below
are as follows:
a = 1–2 e = 1–11
b = 1–2 or ALL f = 1–12 (1–10 for TOTA-5 & TOTA-M)
c = 1–4 or ALL g = 1–10 (1–20 for EA20) or ALL
d = 2–4 (c > b) h = 2–10 (2–20 for EA20) (h > g)
aid parameter value meaning
DCIM-a-b framing CAS channel associated signaling
CAS4 channel associated signaling with cyclic redundancy check 4
CRC4 common channel signaling with cyclic redundancy check 4
D4 D4 framing
ESF ESF framing
FAS common channel signaling
priority 1–4 priority of the reference, 1 is highest priority
reference
type
(null) (not applicable)
signal type ANALOG analog signal
DIGITAL digital signal
reference
condition
ALW this input reference can be used
INH this input reference cannot be used (but can be IS-NR)

Table of Contents

Other manuals for Symmetricom TimeProvider 500 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 500 series and is the answer not in the manual?

Symmetricom TimeProvider 500 series Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 500 series
CategoryData Loggers
LanguageEnglish

Related product manuals