EasyManuals Logo

Symmetricom TimeProvider 500 series Reference Guide

Symmetricom TimeProvider 500 series
165 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #143 background imageLoading...
Page #143 background image
Issue 2: Sep 99 TMSL 097-44018-26
Page 143
COMMAND CODE: SET-REPTMODE-PORT
PURPOSE
SET REPORT MODE PORT
This command sets the message type (REPT-ALM-PORT or REPT-ALM-EQPT) used to report autono-
mous port-alarm messages.
INPUT FORMAT
SET-REPTMODE-PORT:[<tid>]::<ctag>::<modetype>;
Note: Automatic equipment-alarm messages are always reported as REPT-ALM-EQPT messages.
EXAMPLE
Input:
SET-REPTMODE-PORT:::119::ALW;
Response:
SANJOSE-114 1997-12-08 15:04:13
M 119 COMPLD
;
This example, tagged as command 119, sets automatic port-alarm messages to be reported as REPT-
ALM-PORT messages.
modetype meaning
ALW automatic port-alarm messages are reported as REPT-ALM-PORT
messages
INH automatic port-alarm messages are reported as REPT-ALM-EQPT
messages

Table of Contents

Other manuals for Symmetricom TimeProvider 500 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 500 series and is the answer not in the manual?

Symmetricom TimeProvider 500 series Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 500 series
CategoryData Loggers
LanguageEnglish

Related product manuals