TMSL 097-44018-26 Issue 2: Sep 99
Page 142
COMMAND CODE: SET-DA-EQPT
PURPOSE
SET DELAY ACTIVATION EQUIPMENT
This command sets the amount of time from when transmission impairments are detected on an input
until the input is disqualified, and the amount of time from when the input is free of transmission im-
pairments until the input is requalified for use. The command applies to both inputs of a DCIM card.
INPUT FORMAT
SET-DA-EQPT:[<tid>]:<aid>:<ctag>::[<holdoff>],[<rstdur>];
The parameter values in the table below are as follows:
a=12
Caution: If the <holdoff> parameter is set to a value greater than zero and an input is lost,
the output phase may shift an amount that exceeds standards for BITS systems.
EXAMPLE
Input:
SET-DA-EQPT::DCIM-1:137::100,5;
Response:
SANJOSE-114 1997-12-08 15:04:13
M 137 COMPLD
;
This example, tagged as command 137, sets the holdoff delay to 100 ms and the restore delay to 5 min.
parameter value meaning
aid DCIM-a specified DCIM card
holdoff 0–2000 holdoff delay: amount of time (ms) from when a transmission
impairment is detected on an input source until that input is disqualified
(in 100 ms steps)
rstdur 0–15 restore delay: amount of time (min) from when an input source
becomes free of transmission impairments until that input is requalified
for use (in 1 min steps)

Table of Contents

Other manuals for Symmetricom TimeProvider 500 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 500 series and is the answer not in the manual?

Symmetricom TimeProvider 500 series Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 500 series
CategoryData Loggers
LanguageEnglish

Related product manuals