COMMAND CODE: SET-ATTR-PORT (Contd)
INPUT FORMAT
EXAMPLE
Input:
SET-ATTR-PORT::MRC-1-4:137::MJ,AIS;
Response:
SANJOSE-114 1997-12-08 15:04:13
M 137 COMPLD
;
This example, tagged as command 137, sets the alarm indication signal to a major alarm on span 4 of
MRC 1.
aid ntfcncde condtype meaning
PSM-e-
c[&&-d]
CR, MJ, MN, NA, or
NR
AIS alarm indication signal
ALL all condtypes
BPV bipolar violations
CRC cyclic redundancy check errors
LOS loss of signal
MTIE1 1 second threshold
MTIE4 4 second threshold
MTIE16 16 second threshold
MTIE64 64 second threshold
MTIE128 128 second threshold
MTIE512 512 second threshold
MTIE900 900 second threshold
TDEV1 1 second threshold
TDEV4 4 second threshold
TDEV16 16 second threshold
TDEV64 64 second threshold
TDEV128 128 second threshold