EasyManuals Logo

Symmetricom TimeProvider 500 series Reference Guide

Symmetricom TimeProvider 500 series
165 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #75 background imageLoading...
Page #75 background image
Issue 2: Sep 99 TMSL 097-44018-26
Page 75
COMMAND CODE: RLS-SYNCNSW
PURPOSE
RELEASE SYNCHRONIZATION SWITCH
This command cancels the OPR-SYNCNSW command and returns to (hardware control) revertive or
nonrevertive selection mode as determined by the SET-ATTR-CONT command.
INPUT FORMAT
RLS-SYNCNSW:[<tid>]:TO-ALL:<ctag>;
EXAMPLE
Input:
RLS-SYNCNSW::TO-ALL:134;
Response:
SANJOSE-114 95-12-08 15:04:13
M 134 COMPLD
;
This example, tagged as command 134, puts the system in hardware control mode.