Page 132
COMMAND CODE: RTRV-TH-PORT
PURPOSE
RETRIEVE THRESHOLD PORT
This command displays the threshold level for a monitored parameter. When the parameter exceeds the
threshold value, an automatic message is sent. The threshold may apply to one or more units.
INPUT FORMAT
RTRV-TH-PORT:[<tid>]:<aid>:<ctag>::<montype>;
The parameter values in the table below are as follows:
a = 1–2 d = 2–4 (d > c)
b = 1–2 or ALL e = 1–11
c = 1–4 or ALL
aid montype meaning
DCIM-a-b ALL all montypes for this <aid>
BPV bipolar violations
CRC cyclic redundancy check errors
MRC-a-c[&&-d] ALL all montypes for this <aid>
BPV bipolar violations
CRC cyclic redundancy check errors
PSM-e-c[&&-d] ALL all montypes for this <aid>
BPV bipolar violations
CRC cyclic redundancy check errors
MTIE1 1 second threshold
MTIE4 4 second threshold
MTIE16 16 second threshold
MTIE64 64 second threshold
MTIE128 128 second threshold
MTIE512 512 second threshold
MTIE900 900 second threshold
TDEV1 1 second threshold
TDEV4 4 second threshold
TDEV16 16 second threshold
TDEV64 64 second threshold
TDEV128 128 second threshold

Table of Contents

Other manuals for Symmetricom TimeProvider 500 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 500 series and is the answer not in the manual?

Symmetricom TimeProvider 500 series Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 500 series
CategoryData Loggers
LanguageEnglish

Related product manuals