Page 80
COMMAND CODE: RTRV-ALM
PURPOSE
RETRIEVE ALARMS
This command lists all active alarms on any card or port in a system (RTRV-ALM-ALL), specific equip-
ment alarms (RTRV-ALM-EQPT), or specific facilities (RTRV-ALM-PORT). The optional parameters
specify alarms by severity, type, or whether they affect service. If a piece of equipment is not in alarm,
use the RTRV-COND command to retrieve its condition.
INPUT FORMAT
RTRV-ALM-{ALL|EQPT|PORT}:[<tid>]:<aid>:<ctag>;
The following values can be used for the variables in the table below:
a = 1–2 e = 1–4 or ALL
b = 1–11 f = 2–4 (f > e)
c = 1–12 (1–10 for TOTA-5 &TOTA-M) g = 1–10 (1–20 for EA20) or ALL
d = 1–2 or ALL h = 2–10 (2–20 for EA20) (h > g)
command aid
RTRV-ALM-ALL SHELF
RTRV-ALM-EQPT CLK-a
DCIM-a
GTI-a
LT I-a
MCA
MRC-a
PSM-b
SHELF
TO-c
RTRV-ALM-PORT DCIM-a-d
MRC-a-e[&&-f]
PSM-b-e[&&-f]
TO-c-g[&&-h]

Table of Contents

Other manuals for Symmetricom TimeProvider 500 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 500 series and is the answer not in the manual?

Symmetricom TimeProvider 500 series Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 500 series
CategoryData Loggers
LanguageEnglish

Related product manuals