Issue 2: Sep 99 TMSL 097-44018-26
Page 61
COMMAND CODE: INIT-REG
PURPOSE
INITIALIZE REGISTER
This command resets the specified performance-monitoring storage registers (<montype>) on the speci-
fied equipment. These registers contain performance monitoring information accumulated in previous
intervals. After putting ports into service, it is recommended that this command be used to initialize the
performance-monitoring storage registers on those ports to avoid the possibility of invalid data.
INPUT FORMAT
INIT-REG:[<tid>]:<aid>:<ctag>::<montype>;
The parameter values in the table below are as follows:
a = 1–2 c = 2 e = 2–4 (c > b)
b = 1–2 or ALL d = 1–4 or ALL f = 1–11
aid parameter value meaning
ALL montype ALL all spans of all DCIM, MRC, & PSM cards
DCIM-a-b montype ALL all montypes
BPV bipolar violations register
CRC cyclic redundancy check errors register
MRC-a-d[&&-e] montype ALL all montypes
BPV bipolar violations register
CRC cyclic redundancy check errors register
PSM-f-d[&&-e] montype ALL all montypes
BPV bipolar violations register
CRC cyclic redundancy check errors register
MTIE MTIE performance monitoring register
PHASE1M phase 1-minute register
SLIPS slips register
TDEV TDEV performance monitoring register

Table of Contents

Other manuals for Symmetricom TimeProvider 500 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 500 series and is the answer not in the manual?

Symmetricom TimeProvider 500 series Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 500 series
CategoryData Loggers
LanguageEnglish

Related product manuals