COMMAND CODE: RTRV-COND
PURPOSE
RETRIEVE CONDITIONS
This command displays the current standing alarms, events, or state associated with one or more speci-
fied equipment units or facilities.
INPUT FORMAT
RTRV-COND-{EQPT|PORT}:[<tid>]:<aid>:<ctag>;
The following values can be used for the variables in the table below:
a = 1–2 e = 1–4 or ALL
b = 1–11 f = 2–4 (f > e)
c = 1–12 (1–10 for TOTA-5 & TOTA-M) g = 1–10 (1–20 for EA20) or ALL
d = 1–2 or ALL h = 2–10 (2–20 for EA20) (h > g)
RESPONSE FORMAT
<sid> <date> <time>
M <ctag> COMPLD
"<aid>:<ntfcncde>,<typerep>,<srveff>,<conddescr>"...
;
Refer to Table A and Table F for parameter values.
command aid
RTRV-COND-EQPT CLK-a
DCIM-a
GTI-a
LT I - a
MCA
MRC-a
PSM-b
SHELF
TO-c
RTRV-COND-PORT DCIM-a-d
MRC-a-e[&&-f]
PSM-b-e[&&-f]
TO-c-g[&&-h]