COMMAND CODE: ENT-PORT
PURPOSE
ENTER PORT
This command enters a new port including the framing, priority, reference type, signal type, and refer-
ence condition.
INPUT FORMAT
ENT-PORT:[<tid>]:<aid>:<ctag>::<framing>,<priority>,
<reference type>,<signal type>,<reference condition>;
Any parameter left blank causes the card to use switch settings for that parameter. The parameter val-
ues in the table below are as follows:
a = 1–2 e = 1–11
b = 1–2 or ALL f = 1–12 (1–10 for TOTA-5 &TOTA-M)
c = 1–4 or ALL g = 1–10 (1–20 for EA20) or ALL
d = 2–4 (c > b) h = 2–10 (2–20 for EA20) (h > g)
aid parameter value meaning
DCIM-a-b framing CAS channel associated signaling
CAS4 channel associated signaling with cyclic redundancy check 4
CRC4 common channel signaling with cyclic redundancy check 4
D4 D4 framing
ESF ESF framing
FAS common channel signaling
priority 1–4 priority of the reference, 1 is highest priority
reference
type
(null) (not applicable)
signal type ANALOG analog signal
DIGITAL digital signal
reference
condition
ALW this input reference can be used
INH this input reference cannot be used (but can be IS-NR)

Table of Contents

Other manuals for Symmetricom TimeProvider 500 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 500 series and is the answer not in the manual?

Symmetricom TimeProvider 500 series Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 500 series
CategoryData Loggers
LanguageEnglish

Related product manuals