Issue 2: Sep 99 TMSL 097-44018-26
Page 19
COMMAND CODE: CANC-USER
PURPOSE
CANCEL USER
This command logs the user off and ends the session. After a period of inactivity (set in the ED-COM
command), the user is automatically logged off. The user name is case sensitive (uppercase and lower-
case) and must be entered exactly as assigned.
INPUT FORMAT
CANC-USER:[<tid>]:<uid>:<ctag>;
EXAMPLE
Input:
CANC-USER::BIG:155;
Response:
SANJOSE-114 1997-12-08 15:04:13
M 155 COMPLD
;
This example, tagged as command 155, logs user BIG off and ends a session.
parameter value meaning
uid user name the user logging off

Table of Contents