Issue 2: Sep 99 TMSL 097-44018-26
Page 43
COMMAND CODE: ED-PORT (Contd)
INPUT FORMAT (Contd)
EXAMPLE
Input:
ED-PORT::MRC-2-2:154::FAS,4,NETWORK,DIGITAL;
Response:
SANJOSE-114 1997-12-08 15:04:13
M 154 COMPLD
;
This example, tagged as command 154, commands port 2 of MRC 2 to be FAS framing, the lowest priority
reference, and specifies that it is receiving timing from a digital network reference.
Note: If all the reference ports of an MRC card are configured for the same priority, the references
will be selected based on the numerical order of the ports. The same numerical order will be listed if
the settings are retrieved.
aid parameter value meaning
TO-f-g[&&-h] framing (null) (not applicable)
priority
reference
type
signal type ANALOG analog signal (TO-EA5, EA10, & EA20 only)
DIGITAL digital signal
reference
condition
(null) (not applicable)