comtype This parameter indicates the type of communication device used (X25, MODEM, TERM1,
TERM2, or remote). Refer to the ED-COM command for an explanation of device types.
conddescr This parameter is the condition description which is a text description of the alarm or condition
reported by the system, enclosed within /* and */. The system returns one conddescr per
response message. Valid values for <conddescr> are listed in Table F.
condeff This parameter indicates the effect of the event on the condition of the equipment. If a standing
condition is raised, it can be retrieved using the RTRV-COND-EQPT command with an <aid> of
SHELF. A transient condition does not change the basic state of the equipment. Valid values
for <condeff> are:
SC = standing condition raised
CL = standing condition cleared
TC = transient condition
condtype This parameter is the condition type. When used in a command, it indicates the type of alarm
condition requested. When seen in a response, it indicates the type of alarm condition being
reported, which is further explained in the conddescr parameter. When seen in an automatic
message, it indicates the type of alarm condition reported as either raised or cleared (see the
conddescr parameter). Valid values for <condtype> are listed in Table F.
conttype This parameter is the control type. Refer to the SET-ATTR-CONT command for additional infor-
mation.
With an <aid> of DCIM-ALL, this parameter indicates the input protection mode:
NO = no protection: each DCIM card is stand-alone with 2 inputs
1+1 = 1-plus-1 protection: the 2 DCIM cards operate as 1 card with 4 inputs
With an <aid> of MIS, this parameter indicates the SSM mode (applies to master and all
expansions shelves):
NO = SSM is not supported
SSME = SSM supported for DCIM-EA, EA10-M, and EA20-M cards only
SSMT = SSM supported for DCIM-T and TOTA-M cards only
With an <aid> of TO (timing output card), this parameter indicates the output protection mode
(applies to TO-EA5, EA10, and EA20 cards):
NO = no protection
1-1 = 1-for-1 protection
1+1 = 1-plus-1 protection
With an <aid> of SHELF, this parameter indicates the timing output source selection mode
(applies to master and all expansions shelves):
RVRT = revertive
NRVRT = nonrevertive
Table A. Parameter Definitions (Contd)
PARAMETER DEFINITION

Table of Contents

Other manuals for Symmetricom TimeProvider 500 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 500 series and is the answer not in the manual?

Symmetricom TimeProvider 500 series Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 500 series
CategoryData Loggers
LanguageEnglish

Related product manuals