TMSL 097-44018-26 Issue 2: Sep 99
Page 86
COMMAND CODE: RTRV-COM (Contd)
RESPONSE FORMAT (Cont)
parameter value meaning
comtype X25 this port is set for PAD
MODEM this port is set for modem
TERM1 dumb terminal (VT100 with no DSR/DTR support and message buffering dis-
abled)
TERM2 dumb terminal (VT100 with DSR/DTR support and message buffering enabled)
REMOTE allows communication with a remote shelf via the specified communication port
endoftext 0–9F this hexadecimal number sets an additional character as the end-of-text mes-
sage. 0 indicates no end-of-text message. This character does not replace the
TL1 end-of-text terminator (;)
echo ALW local echo is allowed on this port
INH local echo is inhibited on this port
compri INH communication through a port with this designation is inhibited (INH is not al-
lowed on COM2)
ALW0 allows normal communication; autonomous messages are not sent out a port
with this priority level
ALW1 allows normal communication; autonomous messages are always sent out this
port regardless of the priorities of the other ports (this is the highest port priority)
ALW2 allows normal communication; autonomous messages are sent out this port only
if there are no ports with a priority level of ALW1 (this is the second-highest port
priority)
ALW3 allows normal communication; autonomous messages are sent out this port only
if there are no ports with a priority level of ALW1 or ALW2 (this is the lowest port
priority)
hwcontrol ALW external equipment is allowed to stop the DCD system from sending messages
by setting the clear to send (CTS) lead low, or continue messages by setting the
CTS lead high
INH external equipment is inhibited from controlling DCD system messages by ma-
nipulation of the clear to send (CTS) lead
swcontrol ALW user is allowed to use a Control-s key combination to stop the DCD system from
sending messages; also allows the user to use a Control-q key combination to
cause the DCD system to continue sending messages
INH the use of the Control-s and Control-q key sequences to stop and start messag-
es is inhibited
dur 1–45 time in minutes after which a user is logged off if there is no activity
dn 0–32
numeric
characters
the remote PAD address