4. SYSTEM START-UP PROCEDURE
EO3-11106
4. SYSTEM START-UP PROCEDURE
4- 2
PC Transmission Information Setting
Data transmission information setting with a PC connection is performed here.
Any time outside a sale
Mode Lock: BLIND
68 [X] 1 [ST] | POL Watch Timer
| [#]
2 [ST] | Response Watch Timer
| [#]
3 [ST] | Transmission Delay Timer
| [#]
4 [ST] | Transmission Delay Timer 2
| [#]
[AT/TL]
NOTE: When performing the key operation of 68 [X] [AT/TL], a receipt containing the currently programmed
values is issued.
Example) To set the following values;
POL Watch Timer: 30 (sec)
Response Watch Timer: 20 (sec)
Transmission Delay Timer: 4 (80 ms)
Transmission Delay Timer 2: 25 (500 ms)
Key Operation:
Mode Lock: BLIND, enter 68, depress [X].
1 [ST] 30 [#] POL Watch Timer
2 [ST] 20 [#] Response Watch Timer
3 [ST] 4 [#] Transmission Delay Timer
4 [ST] 25 [#] Transmission Delay Timer 2
[AT/TL] To complete this setting
Max. 2 digits: 0 to 99
(Standard: 20 sec.)
Max. 2 digits: 0 to 99
(Standard: 20 sec.)
Max. 2 digits: 0 to 99
(1 = 20 ms)
(Standard: 3 = 60 ms)
2 digits: 15 to 99
(1 = 20 ms)
(Standard: 25 = 500 ms)