FORMA: Service & Maintenance manual - rev. 3.0
Page 7.24
7.20. DISASSEMBLING THE UP-DOWN MOTOR
Figure 7.20-1
1. Carry out the procedure described in
paragraph 7.19. “Disassembling the column
and rubber guard”.
2. Disconnect the motor supply cable a from the
electrical box.
3. Detach its locking strip.
Figure 7.20-2
Overturn the machine on one side:
4. Back off the 2 screws b using 2 4-mm hex T
wrenches.
5. Disconnect the UP-DOWN MOTOR rod
from the up-down frame.
Figure 7.20-3
6. Back off the screw c and the nut d using 2
17-mm wrenches.
7. Remove the UP-DOWN MOTOR.
To reassemble the UP-DOWN MOTOR, carry
out the above steps in reverse order.
During reassembly, be careful not to
overtighten the screw c and the nut d, in
order to allow the UP-DOWN MOTOR
a certain amount of play.

Table of Contents