EasyManua.ls Logo

Technogym Forma - The Up-Down Moves in Only One Direction

Technogym Forma
140 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FORMA: Service & Maintenance manual - rev. 3.0
Page 6.32
6.8. THE UP-DOWN MOVES IN ONLY ONE DIRECTION
The machine displays this error if:
a relay on the driver board is defective;
the CPU board fails to send the enable signal;
the driver board is not able to drive the motor.
THE UP-DOWN MOTOR
MOVES IN ONE
DIRECTION ONLY
3
VDoes the driver board receive the
correct control signal in the inactive
direction?
Check and/or replace
cable FR-12
Are the relays on the driver board in
good condition?
Replace the driver board
NO
YES
4
YES
NO
NO
Replace the CPU board
Does the CPU board send the
correct control signal in the inactive
direction?
Check and/or replace
cable FR-11
YES
1
Does the correct control signal for
the inactive direction reach trailing
connector CN28?
NO
YES
2
Replace the faulty relays

Table of Contents