FORMA: Service & Maintenance manual - rev. 3.0
Page 6.5
(3) As for step (2), but on connector K1 on the CPU board of the display.
(4) As for step (2), but on connector J3 of the driver board.
(5) As for step (2), but on connector J4 of the driver board.
(6) As for step (2), but on portable connector CN28.
(7) Slightly lift up the fast ons on the machine power inlet socket. Place the tester probes between
the live and neutral pins on the same connector. The measured voltage should be 220 VAC.
(8) As for step (7), but on the filter input.
(9) As for step (7), but on the filter output.
(10) As for step (7), but on connector CN39.