FORMA: Service & Maintenance manual - rev. 3.0
Page 6.10
(2) Place the tester probes between the blue – black, blue – brown and black – brown conductors
of the motor cable. The measured resistance should be 4.4 Ohm.
(3) Disconnect the motor cable from the motor and place a tester between its terminals U-V, U-W
and V-W. The measured resistance should be approximately 4.4 Ohm.