4-30
Group 05 Multi-Speed Function Group
Code Parameter Name Setting Range Default Unit
Control Mode
Attribute
V/F SLV
PM
SLV
05-45
Acceleration Time Setting of
Multi Speed 14
0.1~6000.0 10.0 s O O O
05-46
Deceleration Time Setting of
Multi Speed 14
0.1~6000.0 10.0 s O O O
05-47
Acceleration Time Setting of
Multi Speed 15
0.1~6000.0 10.0 s O O O
05-48
Deceleration Time Setting of
Multi Speed 15
0.1~6000.0 10.0 s O O O
Group 06 Automatic Program Operation Parameters
Code Parameter Name Setting Range Default Unit
Control Mode
Attribute
V/F SLV
PM
SLV
06-00
Automatic Operation Mode
Selection
0: Disable
0 - O O X
1: Execute a single cycle operation
mode. Restart speed is based on
the previous stopped speed.
2: Execute continuous cycle
operation mode. Restart speed
is based on the previous stopped
speed.
3: After the completion of a single
cycle, the on-going operation
speed is based on the speed of
the last stage. Restart speed is
based on the previous stopped
speed.
4: Execute a single cycle operation
mode. Restart speed will be
based on the speed of stage 1.
5: Execute continuous cycle
operation mode. Restart speed
will be based on the speed of
stage 1.
6: After the completion of a single
cycle, the on-going operation
speed is based on the speed of
the last stage. Restart speed is
based on the previous stopped
speed.
06-01
Frequency Setting of
Operation-Stage 1
0.00~599.00 (Note8) 5.00 Hz O O X *1
06-02
Frequency Setting of
Operation -Stage 2
0.00~599.00 (Note8) 10.00 Hz O O X *1
06-03
Frequency Setting of
Operation -Stage 3
0.00~599.00 (Note8) 20.00 Hz O O X *1