3-49
Cooling Fan Supply Voltage Selection (400V class)
The inverter input voltage range of the F510 400V class models ranges from 380 to 460Vac. In these
models the cooling fan is directly powered from the power supply. Inverter models F510-4150/ 4175/
4215/ 4250/ 4300/ 4375/ 4425/ 4535/ 4670/ 4800-H3 requires the user to select the correct jumper
position based on the inverter input voltage ("400V" is the default position for these models). Please
select the correct position according to the input voltage. If the voltage setting is too low, the cooling
fan will not provide adequate cooling for the inverter resulting in an over-heat error. If the input
voltage is greater than 460Vac, select the “460V” position.
(1) 400V: 150HP~250HP
(2) 400V:300HP~800HP
4KA69X613W01
DM1
25CN
36CN
32CN
31CN
33CN
34CN
35CN
FU1
220V
440V
S
R
TB3 1
+
220V
26CN
440V
TB4(220V)
380V
400/415
440V
460V
SA4(220V)
2
TB2
JP1 JP2 JP3 JP4
4KA69X571W01
4P108C0010103 VER.04
DM1 25CN
36CN
32CN
31CN
33CN
34CN
35CN
2
FU1
220V
440V
S
TB3
1
+
220V
26CN
440V
TB4(220V)
380V
400/415
440V
460V
SA4