4-134
Group 04 External Analo
Input and Output Parameters
04- 00
AI Input Signal Type
Range
【0】:
AI1 0~10V AI2 0~10V
【1】: AI1 0~10V AI2 4~20mA
【2】: Reserved
【3】: Reserved
【4】: AI1 4~20mA AI2 0~10V
【5】: AI1 4~20mA AI2 4~20mA
04- 09
AI Input Signal Type on I/O expansion card *1
Range
【0】:
AI3 0~10V
【1】: AI3 -10~10V
【2】: AI3 4~20mA
04- 01
AI1 Signal Scanning and Filtering Time
Range
【
0.00~2.00】Sec
04- 02
AI1 Gain
Range
【
0.0~1000.0】%
04- 03
AI1 Bias
Range
【
-100~100.0】%
04- 04 AI negative Characteristics
Range
【0】:
Disable
【1】:
Enable
04- 05
AI2 Function Setting
04- 10
AI3 Function Setting *1
Range
【0】:
Auxiliary Frequency
【1】: Frequency Reference Gain
【2】: Frequency Reference Bias
【3】: Output Voltage Bias
【4】:
Coefficient of Acceleration and Deceleration Reduction
【5】: DC Braking Current*
【6】: Over-Torque Detection Level
【7】: Stall Prevention Level During Running
【8】: Frequency Lower Limit
【9】:
Jump Frequency 4
【10】: Added to AI1
【11】: Positive Torque Limit
【12】: Negative Torque Limit
【13】:
Regenerative Torque Limit
【14】:
Positive / Negative Torque Limit
【15】:
Reserved
【16】:
Torque Compensation
【17】: Reserved
04- 06
AI2 Signal Scanning and Filtering Time
Range
【0.00~2.00】Sec
04- 07
AI2 Gain
Range
【
0.0~1000.0】%
04- 08
AI2 Bias
Range
【-100.0~100.0】%
04- 21
AI3 Signal Scanning and Filtering Time *1
Range
【0.00~2.00】Sec
04- 22
AI3 Gain *1