4-153
Group 06 Automatic Pro
g
ram Operation Parameters
06- 00
Automatic Operation Mode Selection
Range
0: Disable
1, 4: Execute a single cycle operation. Restart speed is based on the previous stopped
speed.
2, 5: Execute continuous cycle operation. Restart speed is based on the previous cycle
stop speed.
3, 6: After completion of a single cycle, the on-going operation speed is based on the
speed of the last stage. Restart speed is based on the previous stopped speed
1 to 3: After a stop the inverter will start with the incomplete step when the run command is
re-applied.
4 to 6: After a stop the inverter will start with the first step of the cycle when the run command
is re-applied.
Automatic operation mode uses frequency reference parameters 05-01, 06-01~06-15, operation time
parameters 06-16 ~ 06-31 and direction of operation parameters 06-32~06-47.
Note: The automatic operation mode is disabled when any of the following functions are enabled:
- Frequency wobbling function
- PID function
- Parameters 06-16 to 06-31 are set to 0.
Notes:
- When automatic operation mode is enabled multi-step speed reference command 1~4
(03-00~03-07=2~5) is disabled.
- Frequency of multi-step speed 0 is set by 05-01.
- Acceleration/deceleration time is set by parameter 00-14 and 00-15 in automatic operation mode.
Automatic operation frequency reference settings
06-01
*Frequency Setting of Operation -Stage 1 *1
06-02 *Frequency Setting of Operation -Stage 2 *1
06-03
*Frequency Setting of Operation -Stage 3 *1
06-04
*Frequency Setting of Operation -Stage 4 *1
06-05 *Frequency Setting of Operation -Stage 5 *1
06-06
*Frequency Setting of Operation -Stage 6 *1
06-07
*Frequency Setting of Operation -Stage 7 *1
06-08 *Frequency Setting of Operation -Stage 8 *1
06-09
*Frequency Setting of Operation -Stage 9 *1
06-10
*Frequency Setting of Operation -Stage 10 *1
06-11 *Frequency Setting of Operation -Stage 11 *1
06-12
*Frequency Setting of Operation -Stage 12 *1
06-13
*Frequency Setting of Operation -Stage 13 *1
06-14 *Frequency Setting of Operation -Stage 14 *1
06-15
*Frequency Setting of Operation -Stage 15 *1
Range
0.00~599.00 Hz
*1: It is operation frequency in inverter software V1.4.
*: (When the motor’s maximum output frequency is over than 300Hz, the frequency resolution is
0.1Hz.)