4-166
07- 19
Direction-Detection Speed Search Operating Current
Range
0~100%
07- 20
Speed Search Operating Current
Range
0~100%
07- 21
Integral Time of Speed Searching
Range
0.1~10.0Sec
07- 22
Delay Time of Speed Search
Range
0.0~20.0Sec
07-23
Voltage Recovery Time
Range
0.1~5.0Sec
07- 24
Direction-Detection Speed Search Selection
Range
0: Disable
1: Enable
07- 26
SLV Speed Search Function
Range
0: Enable
1: Disable
07- 27
Start Selection after Fault during SLV Mode
Range
0: Speed search start
1: Normal Start
07- 28
Start after External Base Block
Range
0:
Speed search start
1:
Normal Start
07- 32
Speed Search Mode Selection
Range
0: Disable
1: Mode1: Start a Speed Search at Power on
2: Mode2: Start Speed Search upon the Motor Run
07- 33
Start Frequency of Speed Search Selection
Range
0: Maximum Output Frequency of Motor
1: Frequency Command
Speed search function is used to find the speed of a coasting motor and continue operation from that point.
The speed search function is active after a momentary power loss.
Speed Search from Multi-function digital inputs
Set the multi-function digital input to external speed search command 1 or 2. External speed search
command 1 (value = 19) and 2 (value = 34) cannot be set at the same time, otherwise "SE02" (digital input
terminal error) warning occurs.
Speed search function must be enabled before applying the run command to ensure proper operation.
See relay logic in Fig. 4.4.54.
Figure 4.4.54 Speed search and operation commands