4-170
07- 29
Run Command Available during DC Braking
Range
0:
Disable (Run command isn’t available until the DC braking is completely done)
1: Enable
After DC braking action starts, if run command selection is set to 0, it will not run until DC braking action
ends.
If run command selection is set to 1, it is not required to wait for the ending of DC braking action. It can run
during DC braking action process.
07- 42
Voltage Limit Gain
Range 0.0~ 50.0%
When output voltage saturation happen, and the motor running is not normal, increase this parameter to
limit the output voltage.
But when this parameter is too big, the output torque maybe not enoughplease decrease this parameter.
07- 43
Short-circuit Braking Time of PM Motor Speed Search
Range
0.00~100.00Sec
07- 44
DC Braking Time of PM Motor Speed Search
Range
0.00~100.00Sec
If the motor is in a rotating state due to inertia and the rotation speed is far below the minimum speed
control range, parameters 07-43 and 07-44 are available to perform braking action to let the motor stop
and then restart.
If the motor is in a rotating state due to inertia and the rotation speed is higher than the minimum speed
control range, the motor starts in a certain searched frequency regardless of the setting value of parameter
07-43 or 07-44.
If parameters 07-43 and 07-44 are set to 0, the motor starts in a certain searched frequency after motor’s
speed search stops regardless of motor’s rotarion speed.
.
07- 45 STP2 Function Selection
Range
0】:STP2 is enabled
1】:STP2 is disabled
If STP2 is enabled, when 00-02=1 and external operation signal is tripped, keypad will display
“Terminal STOP” error when stop command comes from keypad.
If STP2 is disabled, when 00-02=1 and external operation signal is tripped, keypad will not display
“Terminal STOP” error when stop command comes from keypad.