4-260
Group 22: PM Motor Parameters-
only available when PM Control Mode is selected
22- 00
Rated Power of PM Motor
Range
【
0.00~600.00】Kw
22-01
PM motor rated voltage
Range
200V: 【
50 ~ 240】V
400V: 【10
0 ~ 480】V
22- 02
Rated Current of PM Motor
Range
25%~200% of inverter’s rated current
22- 03
Pole Number of PM Motor
Range
【2~96】Poles
22- 04
Rated Rotation Speed of PM Motor
Range
【6~60000】rpm
22- 05
Maximum Rotation Speed of PM Motor
Range
【6~60000】rpm
22- 06
PM Motor Rated Frequency
Range
【4.8~599.0】Hz
22- 07
PM type selection
Range
【0】SPM
【1】IPM
22- 10
PM SLV Start Current
Range
【20 ~ 200】%
22- 11
I/F Mode Start Frequency Switching Point
Range
【10 ~ 100】%
22- 14
PM Motor Armature Resistance
Range
【0.001 ~ 30.000】Ω
22- 15
PM Motor D-axis Inductance
Range
【0.01 ~ 300.00】mH
22- 16
PM Motor Q-axis Inductance
Range
【0.01 ~ 300.00】mH
22- 17
PM No-Load Voltage
Range
200V: 【0 ~ 200】V
400V: 【0 ~ 400】V
22- 18
Flux-weakening Current Command Restriction
Range
【0 ~ 100】%
*2: It is reserved in inverter software V1.4.
The PM parameter group can be restored to factory default be initializing the inverter (13-08).
1. PM motor rated power (22-00); PM motor rated voltage (22-01); PM motor rated current (22-02)
Setting the motor nameplate value.
2. PM motor pole number (22-03); PM motor rated rotation speed (22-04); PM motor rated frequency
(22-06). Setting the motor nameplate value. For the PM motor rated rotation speed (22-04) and the
PM motor rated frequency (22-06), just set one of the two and the program will automatically
calculate the other. When setting the PM motor rated rotation speed (22-04), the PM motor’s
maximum rotation speed (22-05) will synchronize and update to the same setting. When using the
flux-weakening function, the PM motor’s maximum rotation speed (22-05) setting value must be
revised. The formula is as follows: