7.2 ENTERING-EXITING INSTALLER PROGRAM AND MASTER PROGRAM
To enter the engineering program, press [Fx] then [4], a long beep sounds and enter the engineer
password. The device enters the “Installer Program”. Program LED on LED Keypad, Ready light
flashes. LCD keypads display "INSTALLER MENU".
To enter the Installer Program;
Press [Fx] then Press [4] enter Installer Code (XXXX)
Factory Default of Installer Code is = 9999
To enter the master program, press [Fx] then [4], a long beep sounds and enter the master code. The
device enters the “Master Program”. Program LED on LED Keypad, Ready light flashes. LCD keypads
display "MASTER MENU".
To enter the Master Program;
Press [Fx] then Press [4] enter Master Code (XXXX)
Factory Default of Master Code is = 1234
To exit the program, hold down the X (Exit) key until a long beep sounds and the device returns to
normal. Program LED off.
PS: If no commands are sent to the panel within 3 minutes after programming, the panel
automatically exits the “Program” position and returns to normal.
7.3 BASIC SETTINGS
This is the section where the basic settings such as date - time, delay times and telephone numbers
are made.
7.3.1 Time/Date Settings
The Control Panel's Time and Date settings are made in this step, a panel without a time and date
setting turns on the Trouble LED and gives an error warning. Error settings are automatically
removed when these settings are made.
Setting the Time
• LED Keypad; [01] [01] → [HH: MM] → [√ OK]
• LCD Keypad; [Basic Settings √ OK] → [Time/Date Settings √ OK] → [HH: MM] → [√ OK]
eg. To set time 09:05 with LED Keypad; [01] [01] [09] [05] [√ OK]
Setting the Date
• LED Keypad; [01] [02] → [DD:MM:YY] → [√ OK]
• LCD Keypad; [Basic Settings √ OK] → [Time/Date Settings √ OK] → [DD:MM:YY] → [√ OK]
eg. To set date 10.11.2019 with LED Keypad; [01] [02] [10] [11] [19] [√ OK]