EasyManua.ls Logo

Teknim PARS Series - Hareketsi̇zli̇kte Otomati̇k Alarm Kurma

Teknim PARS Series
81 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
66 / 81
First of all, it is necessary to assign the zones to the relevant partitions in order to define the
partition. If no zone is assigned, all zones are defined in partition A and the system is used with a
single partition.
To assigned the zones to a related partition see the section 7.5 Zone Settings - 7.5.2 Partition
Separate Entry-Exit time can be defined in each Partitions. In this way, different partitions can be
arm-disarm at different times.
To set different Entry-Exit times for partitions see the section 7.3 Basic Settings 7.3.2 Exit
Delays and 7.3.3 Exit Delays.
If more than one Keypad is to be used, settings should be made on which Keypad is authorized for
which partition. In this way, any partition with an unauthorized keypad can be prevented from
performing arming and disarming.
PS: A Keypad can be authorized for a single partition or can be authorized for multiple partitions.
To assigned Keypads to Partitions see the section 7.6 Keypad Settings 7.6.2 Keypad
Partitions.
By specifying which users are authorized in which partitions, specific users can be arm and disarm
the partitions their assigned only. This will prevent the unauthorized user from arm and disarm the
relevant partition.
To assigned users to partitions see the section 7.7 User Settings - 7.7.4 User Partitions.
For each partitions, AHM reports, user phone calls and SMS notifications can be forwarded to
different user numbers. In this way, users can receive alarm notifications only from the
departments they are authorized.
To set notifications according to partitions see the section 7.8 Communicator Settings - 7.8.1
General Settings.
11.4 HAREKETSİZLİKTE OTOMATİK ALARM KURMA
Sistemin kurulu olduğu mahalde, belirli bir süre boyunca herhangi bir hareket algılanmaz ise
sistemin otomatik olarak kurulması sağlanabilir. Bu sayede yüksek güvenlik gerektiren yerler için
alarm sisteminin kurulmasının unutulmuş olması gibi durumlarda sistem belirlenen bir süre içeride
herhangi bir hareket algılamaz ise sistemi otomatik olarak kurar.
Hangi bölümlerin hareketsizlik durumunda otomatik kurulacağı aşağıdaki gibi seçilir.
LED Keypad;
[12] [07] [1-2-3-4] [√ OK]
LCD Keypad;
[Panel Settings OK][Auto Arm/Disarm OK][Inactivity Arm A-B-C-D][ OK]