8. PROGRAMMING TABLE
This table shows all the functions and the factory settings that can be made on the panel.
<InP> Installer Menu with Installer Code Factory Default: 9999
<MaP> Master Menu with Master Code Factory Default: 1234
ADDRESS
FUNCTION
VALUE - SETTINGS
FACTORY
DEFAULT
ACCESS
AUTHORITY
0 BASIC SETTINGS
01 TIME / DATE SETTINGS
01 01
Time
HH:MM HH: Hour, MM: Minute
00:00
InP & MaP
01 02
Date
DD MM YY DD: Day, MM: Month, YY: Last Two Digit of the
Year
00.00.00
InP & MaP
02 ENTRANCE DELAYS
02 01
02 02
02 03
02 04
Partition A
Partition B
Partition C
Partition D
0~255 Second
15
0
0
0
InP
03 EXIT DELAYS
03 01
03 02
03 03
03 04
Partition A
Partition B
Partition C
Partition D
0~255 Second
15
0
0
0
InP
04 CMS ACCOUNT NO
04 01
04 02
CMS 1
CMS 2
4 Digit Account Number
0000
0000
InP
05 CMS PHONE NUMBER
05 01
05 02
05 03
05 04
CMS 1
CMS 2
Backup CMS 1
Backup CMS 2
Up to 15 Digit Phone Number (Including space)
0 (press long) can give you space if you need time to wait for
line.
To erase the phone number press and hold [B].
Empty
Empty
Empty
Empty
InP
06 USER PHONE NUMBER
06 01
06 02
06 03
06 04
06 05
06 06
1. User Phone Number
2. User Phone Number
3. User Phone Number
4. User Phone Number
5. User Phone Number
6. User Phone Number
Up to 15 Digit Phone Number (Including space)
0 (press long) can give you space if you need time to wait for
line.
To erase the phone number press and hold [B].
Empty
Empty
Empty
Empty
Empty
Empty
InP
07 USER CODES
07 01
07 02
07 03
07 04
07 05
07 06
07 07
07 08
07 09
07 10
07 11
1. User Code
2. User Code
3. User Code
4. User Code
5. User Code
6. User Code
7. User Code
8. User Code
9. User Code
10. User Code
11. Threat (Duress) Code
4 Digit Code
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
MaP
1 PANEL SETTINGS
10 GENERAL SETTINGS
10 01
Panel Options
2. Option: Quick Arm On/Off
3. Option: Auto Siren Test On/Off
4. Option: Arm/Disarm From Different Keypad On/Off
5. Option: Exit Delay Extension On/Off
6. Option: Double Hit On/Off
2
InP
10 02
Output Polarization
1. Option: PGM- NC/NO
4. Option: SRN- NC/NO (+/- Trigger)
1. NO
2. NO
InP