EasyManua.ls Logo

Teknim PARS Series - Remote Access; Panel Info

Teknim PARS Series
81 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
33 / 81
PS: Days of the week are; 1: Sunday 2: Monday 3: Tuesday 4: Wednesday 5: Thursday 6: Friday
7: Saturday.
Timer 2 Time
This setting determines the days that PGM will be activated.
LED Keypad; [14] [06] [HH:MM] [OK]
LCD Keypad; [Panel Settings OK] [Timer Settings OK] [Timer 2 Time HH:MM] [√ OK]
7.4.6 Remote Access
This section contains settings for remote control of the alarm panel by phone and settings for usage
of the Cloud Communication.
Remote Control Settings
Use the option 1 to turn on or off remote alarm panel access by phone. And option 2 to open or close
the Cloud communication.
LED Keypad; [15] [01] [1-2] [√ OK]
LCD Keypad; [Panel Settings OK] [Remote Access OK] [Rem. Cont. Sett. 1-2] [√ OK]
Ring Count
It determines ring numbers after control panel response by remote control with Phone.
LED Keypad; [15] [02] [X] [ OK]
LCD Keypad; [Panel Settings OK] [Remote Access OK] [Ring Count Time X] [√ OK]
7.4.7 Panel Info
This is where you can access basic information about the alarm panel. No settings can be made in
this section, only readable information.
Basic Informations are; Panel Type, Software Version, Hardware Version.
LED Keypad;
[16] [01] [Panel Type] [OK]
[16] [02] [SW Version] [√ OK]
[16] [03] [HW Version] [OK]
LCD Keypad;
[Panel Settings OK] [Panel Info Ok] [Panel Type] [√ OK]
[Panel Settings OK] [Panel Info Ok] [SW Version] [√ OK]
[Panel Settings OK] [Panel Info Ok] [HW Version] [√ OK]
Option
1.
2.
Feature
Access by Phone
Cloud Connection
LED ON
Yes
Active
LED OFF
NO
Passive

Table of Contents

Related product manuals