TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
33 / 81
PS: Days of the week are; 1: Sunday 2: Monday 3: Tuesday 4: Wednesday 5: Thursday 6: Friday
7: Saturday.
Timer 2 Time
This setting determines the days that PGM will be activated.
• LED Keypad; [14] [06] → [HH:MM] → [√ OK]
• LCD Keypad; [Panel Settings √ OK] → [Timer Settings √ OK] → [Timer 2 Time HH:MM] → [√ OK]
7.4.6 Remote Access
This section contains settings for remote control of the alarm panel by phone and settings for usage
of the Cloud Communication.
Remote Control Settings
Use the option 1 to turn on or off remote alarm panel access by phone. And option 2 to open or close
the Cloud communication.
• LED Keypad; [15] [01] → [1-2] → [√ OK]
• LCD Keypad; [Panel Settings √ OK] → [Remote Access √ OK] → [Rem. Cont. Sett. 1-2] → [√ OK]
Ring Count
It determines ring numbers after control panel response by remote control with Phone.
• LED Keypad; [15] [02] → [X] → [√ OK]
• LCD Keypad; [Panel Settings √ OK] → [Remote Access √ OK] → [Ring Count Time X] → [√ OK]
7.4.7 Panel Info
This is where you can access basic information about the alarm panel. No settings can be made in
this section, only readable information.
Basic Informations are; Panel Type, Software Version, Hardware Version.
• LED Keypad;
[16] [01] → [Panel Type] → [√ OK]
[16] [02] → [SW Version] → [√ OK]
[16] [03] → [HW Version] → [√ OK]
• LCD Keypad;
[Panel Settings √ OK] → [Panel Info √ Ok] → [Panel Type] → [√ OK]
[Panel Settings √ OK] → [Panel Info √ Ok] → [SW Version] → [√ OK]
[Panel Settings √ OK] → [Panel Info √ Ok] → [HW Version] → [√ OK]
Option
1.
2.
Feature
Access by Phone
Cloud Connection
LED ON
Yes
Active
LED OFF
NO
Passive

Table of Contents