TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
30 / 81
Inactivity Arm Delay
You can select the inactivity time in this section. System will be automatically armed if there will be
no movement in this time period. It can be set between 5 255min.
LED Keypad;
[12] [08] [DD] [√ OK]
LCD Keypad;
[Panel Settings OK][ Auto Arm/Disarm OK][ Inactivity Arm Delay DD] [√ OK]
7.4.4 PGM Settings
This section contains settings for using PGM. Each PGM has a usage type and a PGM parameter that
makes sense according to that usage type. In order for the PGM to function as required, both the
usage type and parameter must be set.
Use PGM 1 as
You can choose PGM types in this section.
No
Type
Parameter
Value
1
Manual
PGM can be use by manually. No need to set any value.
-
2
Zone Output
PGM activated when the selected zone is active. Values in the table are
entered in programming to determine which zone to activate.
To select multiple zones, the values
of the two zones are added.
eg. For Z3 and Z6, add both values
4+32= 36.
Zone
Value
Zone
Value
Z1
1
Z5
16
Z2
2
Z6
32
Z3
4
Z7
64
Z4
8
Z8
128
255
3
Partition Output
PGM activated when an alarm occurs in the
selected partition(s). To select the relevant
partition(s), the values in the table are added.
eg. For partition B and C, add and enter 2+4=6.
Partition
Value
A
1
B
2
C
4
D
8
15
4
ARM Status
PGM activated when the selected partition(s) is
armed. To select the relevant partition(s), the
values in the table are added.
eg. For partition B and C, add and enter 2+4=6.
Partition
Value
A
1
B
2
C
4
D
8
15
5
Firen Siren
PGM activated continuously when fire alarm occurs, no value is entered.
-
6
Fire Sensor
Power
When the fire detector supply is used via PGM, the reset time of the PGM
is entered with the password. Can be entered between 1-255 sec. You can
reset the fire detectors when it gives alarm by user codes.
10
7
Siren
PGM is used as a siren output for the selected
partition(s). To select the relevant partition(s), the
values in the table are added together and
entered.
eg. A ve C bölümleri için 1+4=5 değeri girilir.
Partition
Value
A
1
B
2
C
4
D
8
15