TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
31 / 81
8
Trouble Output
PGM is active when selected
errors occur.
Fault
Value
Fault
Value
Mains
Fail
1
Phone
Line
Fail
8
Low
Battery
2
Zone
Fault
16
Time
Not Set
4
Battery
Fault
32
63
9
Access Control
Door lock open hold time can be entered in the range of 1-255 sec.
5
10
Timer Output
The PGM remains on for the specified time and then turns off. Can be
entered between 1-255 sec.
0
11
Random
PGM will open and close
randomly according to the
entered value.
Value
PGM ON
PGM OFF
0
1-255 sec.
1-255 sec.
1
1-255 min.
1-255 min.
2
1-63 sec.
1-255 sec.
3
1-63 min.
1-255 min.
0
12
Arm Indicator
When the alarm system is armed, PGM remains open for the entered
parameter value. Parameter can be entered between 0-255min.
0
13
Disarm Indicator
When the alarm system is disrmed, the PGM remains on until the entered
parameter value. Parameter can be entered between 0-255min.
0
14
Toggle RC Button
PGM activated by remote control. Parameter can be entered between 0-
255min.
0
15
Alarm Type
PGM is activated
according to the selected
alarm type.
Alarm Type
Value
Alarm Type
Value
Intruder
1
Duress
8
Panic
2
Tamper
16
Fire
4
Medical
32
63
LED Keypad;
[13] [01] [0-1-2--15] [√ OK]
LCD Keypad;
[Panel Settings OK][PGM Settings OK][User PGM 1 As {Select Value by (B) (C) Keys}][√ OK]
PGM Settings
PGM parameter varies according to the selected PGM type. The table above shows what this
parameter means and the setting options for each PGM type. If more than one option is selected, the
sum of the values corresponding to the options must be entered.
LED Keypad;
[13] [02] [XXX] [√ OK]
LCD Keypad;
[Panel Settings OK][PGM Settings OK][PGM Settings XXX][ OK]
eg. If PGM is selected as Alarm type and is required to be active in Fire alarm and Medical alarm conditions;
The value specified for the fire alarm (4) and the value specified for the medical alarm (32) are added and the
value found (36) is entered. [13] [02] [36] [√ OK]