EasyManua.ls Logo

Teknim PARS Series - 5 System Features

Teknim PARS Series
81 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
7 / 81
5. SYSTEM FEATURES
Inputs;
TSP-5314
TSP-5324
TSP-5208
Zone
4
4
8
Double Zone
Yes (8)
Yes (8)
Yes (8)
Zone Connection
NC-NO-Resistence Free
NC-NO-Resistence Free
NC-NO-Resistence Free
Keypad Zone
Var
Var
Var
Outputs;
TSP-5324
TSP-5208
PGM Outputs
1 (NC-NO)
1 (NC-NO)
Siren Outputs
1
1
Siren Time
2-255 Sec
2-255 Sec
Electric Mechanic;
TSP-5314
TSP-5324
TSP-5208
Power
230VAC 50Hz
230VAC 50Hz
230VAC 50Hz
Panel Fuse
125mA
125mA
125mA
Circuit Protection
Yes
Yes
Yes
Siren Out
500mA
500mA
500mA
AUX Out
750mA
750mA
750mA
PGM Out
500mA
500mA
500mA
Panel Voltage
12V
12V
12V
Output Current
1,5A
1,5A
1,5A
Dimentions
W: 260mm H: 300mm D:
39/95mm
G: 260mm Y: 300mm D:
39/95mm
G: 260mm Y: 300mm
D: 39/95mm
Weight
1690gr (Unpacked)
1980gr (Packed)
1690gr (Unpacked)
1980gr (Packed)
1690gr (Unpacked)
1980gr (Packed)
Keypad;
TSK-5710
TSK-5718
Keypad Support
4
4
Special Keys
Panic, Fire, Medical
Panic, Fire, Medical
LCD
Yes
No
LED
No
Yes
Keypad Backlit
Yes
Yes
LED Indicator
Yes
Yes
Event Memory
Yes
Yes
Chime
Yes
Yes
Dimensions
W: 171,5mm H: 120mm D: 20/36mm
W: 171,5mm H: 120mm D: 20/36mm

Table of Contents