TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
37 / 81
LED Keypad;
Zone 1 - [22] [01] [XX] [OK]
Zone 2 - [22] [02] [XX] [OK]
Zone 3 - [22] [03] [XX] [OK]
Zone 4 - [22] [04] [XX] [OK]
Zone 5 - [22] [05] [XX] [OK]
Zone 6 - [22] [06] [XX] [OK]
Zone 7 - [22] [07] [XX] [OK]
Zone 8 - [22] [08] [XX] [OK]
LCD Keypad;
[Zone Settings OK] [Zone Type OK] [1- Zone Type] [√ OK]
[Zone Settings OK] [Zone Type OK] [2- Zone Type] [√ OK]
[Zone Settings OK] [Zone Type OK] [3- Zone Type] [√ OK]
[Zone Settings OK] [Zone Type OK] [4- Zone Type] [√ OK]
[Zone Settings OK] [Zone Type OK] [5- Zone Type] [√ OK]
[Zone Settings OK] [Zone Type OK] [6- Zone Type] [√ OK]
[Zone Settings OK] [Zone Type OK] [7- Zone Type] [√ OK]
[Zone Settings OK] [Zone Type OK] [8- Zone Type] [√ OK]
7.5.4 Extra Settings
This is the section where settings for zone behavior are made.
Option
1.
2.
3.
4.
5.
6.
7.
LED ON
Last Door
Zone ON
Follower
Zone ON
Entry Exit
Zone ON
Silent
Zone ON
Bypass Not
Allowed
Include Home
Arming
Cross
Zone ON
LED OFF
Last Door
Zone OFF
Follower
Zone OFF
Entry Exit
Zone OFF
Silent
Zone Off
Bypass
Allowed
Not Include
Home Arming
Cross
Zone OFF
Last Door Zone; When exit from the zone selected as the last door, alarm system will armed
immidiatly without waiting for exit delay ends. Last Door selected zone is automatically set as
Input-Output Zone.
Follower Zone; This zone follows the Input- Output zone. If Input- output zone activated before
followe zone, the follower zone gives entry exit delay. But if the follower zone activated before
input output zone, it gives alarm instantly.
Input - Output Zone; It gives entry delay if the system already armed and waiting for disarm or
gives exit delay if the system will be armed and leave the pleace.
Silent Zone; This zone will not trigger any sounder but it send alarm information to CMS.
Bypass Allowed Not Allowed ; It allowes the bypass key if related zone can be bypass or not.
Include Home Arming; If this option is selected for any zone, when the system armed with Stay
mode, this zones will not work. This feature is used when the users arming the system while they
still inside the place.
Cross Zone; If two or more triggers are triggered during the cross-zone detection period, the panel
switches to alarms if the zones selected as Cross-Zone. If double hit selected, this activation trigger
should be triggered same detector during the cross zone period. But if double hit is not selected,
second trigger should triggered from cross zone in the same partition. If there will be no second
trigger in the time period of cross zone, panel gives Cross Zone Fault.