TEKNİM PARS SERIES INTRUDER ALARM SYSTEM INSTALLATION AND PROGRAMMING MANUAL
On TSK-5718 Keypad, 1-2-3-4-5-6-
7-8 and Trouble lights blink
simultaneously.
Check keypad connection and keypad address. The total
length of the keypad cable should not exceed 100 meters.
If you have connected more than one keypad to the
system, enter the Installer program from the number
Keypad number 1. Check the 2nd, 3rd and 4th keypad
addresses. In program at the 3002, 3003, 3004 address,
option 1 must be active. In this case, 2nd, 3rd and 4th
keypads will work.
I get “Connecting” Fault on
Keypad.
1: Make sure the keypad is properly connected.
2: Make sure that the keypad address is given and that
there are no other keypads on the same line with same
address.
3: Make sure the USB cable is not connected to the panel.
4: Make sure that the USB-PC connector is not connected.
How many keypad zones can I use
on the alarm panel?
There is 1 zone for each keypad. Keypad zones can be
used up to the number of keypads connected to the
system. Max. 4 keypad zones can be used. In order to
activate the keypad zone, the alarm terminals of the
detector must be connected to the mag and gnd terminals
on the keypad and the power must be supplied from Aux.
Zone names do not appear on
other keypads.
Zone information is stored on the keypad and must be set
for each keypad. You cannot view from other keypads or
PC.
Why the keypad zone does not
work.
Keypad zones are closed as a factory default. You must
activate them first.
How many keypads can I use in an
alarm panel?
You can use 4 keypads. LCD or LED keypad does not
matter, the last keypade termination jumper must be
installed and the cable length of keypads should not
exceed 100 mt.
User Calls and SMS does not work
when I change the Sim card on the
GSM-GPRS module.
When you replace the sim card, press and hold the button
on the module for 3s.
I bought the TSP-5208P alarm
panel but I want to switch to GSM
module what should I do?
You can use TXM-5272 to use GSM line in the system.
Although there is no SIM card in
the GSM-GPRS module, the signal
strength is visible.
If the GSM module does not have a simcard, it switches to
emergency mode, connects to the nearest base station
and accesses the signal level.